Product Description:
The special aluminum-plastic blister packaging machine and heat sealing machine circulation chiller is a chiller specially used for packaging machine equipment, mainly used to provide cooling water circulation for the packaging machine and maintain the normal operating temperature of the equipment.
The chiller generally consists of the following parts:
1. Circulating water system: composed of water pumps, water tanks, water pipes, etc., used to circulate water into the packaging machine equipment for cooling.
2. Refrigeration system: composed of compressor, condenser, evaporator, etc., used to cool down the circulating water and discharge the heat.
3. Control system: used to monitor and adjust the operating status of the chiller to ensure its normal operation.
Production Features:
The characteristics of the special aluminum-plastic blister packaging machine and the heat-sealing machine circulating chiller are:
1. Strong stability: Using high-quality compressors and other key components, it can run stably and provide continuous cooling effect.
2. Energy saving and environmental protection: the use of high-efficiency energy-saving technology and design can reduce energy consumption and reduce the impact on the environment.
3. Simple operation: Equipped with an intelligent control system, users can easily operate and monitor.
4. Strong adaptability: the chiller can be customized according to the needs of packaging machine equipment, and is suitable for different types and specifications of packaging machine equipment.
Working Principle:
The working principle of the water-cooled chiller is to use the physical changes of the refrigerant in the refrigeration cycle to achieve the cooling effect. The specific process is as follows:
1.Compression process: The compressor in the water-cooled chiller sucks in low-temperature and low-pressure refrigerant gas, and compresses it into high-temperature and high-pressure gas through compression.
2.Condensation process: The high-temperature and high-pressure gas dissipates heat through the condenser and becomes a high-temperature and high-pressure liquid.
3.Expansion process: The high-temperature and high-pressure liquid enters the evaporator through the expansion valve. Due to the throttling effect of the expansion valve, the pressure and temperature of the liquid refrigerant decrease rapidly, thus turning into a low-temperature and low-pressure refrigerant vapor.
4.Evaporation process: The low-temperature and low-pressure refrigerant vapor exchanges heat with the cold water in the evaporator, thereby reducing the temperature of the cold water.
5.Circulation process: cold water circulates through the pipes and continuously absorbs the refrigerant vapor in the evaporator to achieve cooling effect. At the same time, the refrigerant vapor returns to the compressor after absorbing the heat of the cold water, forming a reciprocating refrigeration process.
In short, the working principle of the water-cooled chiller is to use the physical changes of the refrigerant in the refrigeration cycle to achieve the cooling effect. Through the processes of compression, condensation, expansion and evaporation, the refrigerant is recycled to continuously absorb and release heat, thus Realize the cooling of cold water.
① Compressor | ⑤ Evaporator | ⑨ Temperature sensor | ⑬ Bypass valve |
② Condenser | ⑥ Ball valve | ⑩ Water tank | ⑭ Low voltage controller |
③ Filter drier | ⑦ Antifreeze switch | ⑪ Water pump pressure gauge | ⑮ High voltage controller |
④ Expansion valve | ⑧ Float switch | ⑫ Water pump | ⑯ Pressure relief valve |
Techinical Parameters:
Model | JLSS-5HP | JLSS-10HP | JLSS-15HP | JLSS-20HP | JLSS-25HP | JLSS-30HP | JLSS-40HP | JLSS-50HP | ||
Cooling capacity | KW/h | 16.2 | 32.5 | 48.7 | 64.2 | 81.2 | 97.4 | 130.3 | 163.4 | |
Kcal/h | 14,200 | 28,400 | 42,600 | 56,800 | 71,000 | 85,200 | 113,600 | 142,000 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 4.17 | 8.25 | 12.75 | 18.2 | 20.95 | 26.5 | 35.6 | 43.2 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 3.75 | 7.5 | 11.25 | 15.0 | 18.75 | 22.5 | 30.0 | 37.5 | |
Circulating pump | Power | KW | 0.75 | 1.5 | 1.5 | 2.25 | 2.25 | 3.75 | 3.75 | 3.75 |
Head | m | 22 | 21.5 | 21.5 | 23 | 23 | 23 | 25 | 25 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 2.6 | 5.2 | 7.8 | 10.4 | 13.0 | 15.6 | 20.8 | 26.0 | |
Evaporator | Flow | m³/h | 2.75 | 5.47 | 8.62 | 11.55 | 14.03 | 17.06 | 22.19 | 26.48 |
water capacity | m³ | 0.058 | 0.150 | 0.285 | 0.300 | 0.380 | 0.380 | 0.560 | 0.560 | |
Diameter | inch | 1" | 1.5" | 2" | 2.5" | 2.5" | 3" | 3" | 3" | |
Compressor | Type | m³/h | Efficient copper shell and tube type | |||||||
Flow | m³/h | 3.42 | 6.85 | 10.78 | 14.44 | 17.54 | 21.32 | 27.74 | 33.09 | |
Diameter | inch | 1" | 1.5" | 2" | 2.5" | 2.5" | 3" | 3" | 3" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 850 | 1300 | 1600 | 1600 | 1600 | 1800 | 2400 | 2400 |
W | mm | 480 | 610 | 700 | 730 | 730 | 760 | 1000 | 1000 | |
H | mm | 980 | 1260 | 1400 | 1500 | 1500 | 1600 | 1750 | 1750 | |
Unit weight | Kg | 60 | 150 | 400 | 440 | 690 | 760 | 850 | 1000 |
Application Industry:
Water-cooled chillers are suitable for industrial and commercial areas that require a lot of refrigeration, such as:
1.Manufacturing industry: Water-cooled chillers can be used for refrigeration of equipment and production lines in manufacturing industries such as metal processing, plastic processing, and food processing.
2.Chemical industry: Water-cooled chillers can be used for equipment and reactors that need to be cooled in the chemical production process.
3.Pharmaceutical industry: Water-cooled chillers can be used for cooling and freezing processes in the pharmaceutical industry.
4.Cold storage: Water-cooled chillers can be used in cold storage and other places that require a lot of refrigeration and keep low temperature.
5.Commercial buildings: Water-cooled chillers can be used in large commercial buildings, such as shopping malls, office buildings, hotels, etc.
6.Hospitals: Water-cooled chillers can be used in hospital operating rooms, wards and other places that need to be kept low and dry.
7.Electronics industry: Water-cooled chillers can be used for equipment cooling and temperature control in the electronics industry.
In short, water-cooled chillers are widely used in many fields, and can provide efficient, stable and reliable refrigeration services for various equipment and places.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
Product Maintenance:
It should be noted that the following points should be paid attention to when using special aluminum-plastic blister packaging machines and heat-sealing machine circulating chillers:
1. Water quality: The water quality of the circulating chiller should be clean and hygienic, and water containing corrosive substances and impurities should not be used.
2. Maintenance: Regularly maintain the chiller, clean the condenser and evaporator and other components to ensure its normal operation.
3. Safe operation: Operators should have relevant skills and knowledge, and take corresponding safety measures to ensure safe production.