Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Air Cooled Screw Chiller /

JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control

Contact Now
Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrJlschiller
Contact Now

JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control

Ask Latest Price
Video Channel
Brand Name :JIALIS
Model Number :JLSF-75D
Certification :CE/ISO9001
Place of Origin :Dongguan China
MOQ :1 set
Price :Discuss
Payment Terms :T/T
Supply Ability :50 units per month
Delivery Time :20 days
Packaging Details :Plywood wooden box
Product Name :Air Cooled Scroll Chiller
Ambient Temperature :5-35℃
Compressor Motor Power :37-250kW
Compressor Quantity :3
Condenser :Finned Tube Heat Exchanger
Control System :Microcomputer Control
Cooling Capacity :150-1000kW
Cooling Method :Air Cooled
Evaporator :Shell & Tube/ Plate Heat Exchanger
Noise Level :≤75dB(A)
Refrigerant :R22/R407C/R410A
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

JLSF-75D Air Cooled Water Chillers,Danfoss Scroll Compressor Stable Performance

Product Description:


The air-cooled scroll chiller is a chiller that uses a scroll compressor and air-cooled heat dissipation. It uses a scroll compressor to compress low-temperature refrigerant into high-temperature and high-pressure gas, and then dissipates the heat to the surrounding environment through an air-cooled radiator to achieve a cooling effect.

Scroll compressors are a high-efficiency, low-noise compressor type. Compared with traditional reciprocating compressors, scroll compressors have higher compression ratios and lower vibration noise. It uses a vortex-like rotating action to quickly compress and discharge the refrigerant, providing a high-pressure and high-flow refrigerant supply.

An air-cooled radiator is a cooling device that uses natural wind or fans to transfer heat to the surrounding environment. It usually consists of a heat sink and a fan. It takes away heat from the chiller and lowers the temperature through air blowing against the heat sink and convection heat transfer.

JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control

Production Features:


The main advantages of air-cooled scroll chillers include:

1. High efficiency and energy saving: It adopts scroll compressor, which has high compression efficiency and can provide higher refrigeration capacity and efficiency. At the same time, the air-cooled heat dissipation method avoids the water pumps and cooling towers of traditional water-cooling systems, reducing energy consumption and maintenance costs.

2. Flexibility and convenience: Since there is no need to connect to the cooling water source, the air-cooled scroll chiller is not restricted by the cooling water pipeline, and installation and debugging are relatively simple. It is suitable for various places, whether it is industrial production workshop or commercial office space.

3. Reliability and stability: The scroll compressor has a simple structure, which reduces the wear and failure rate of mechanical parts and improves the reliability of the system. At the same time, the air-cooled radiator does not rely on external cooling water sources, avoiding leakage and water quality problems that may occur in the water-cooling system.

4. Space saving: Since there is no need for cooling water tanks and cooling towers, air-cooled scroll chillers can save installation space and are especially suitable for places with limited space.

It should be noted that air-cooled scroll chillers may have a slight disadvantage in heat dissipation compared to water-cooled systems, especially under high ambient temperatures or high-load operating conditions. Therefore, when selecting a chiller, comprehensive considerations need to be made based on specific application requirements and environmental conditions.

Working Principle:


The working principle of the air-cooled scroll chiller is as follows:

1. Compression process: First, the scroll compressor starts working. The vortex rotor inside it draws low-temperature refrigerant into the compression chamber through self-rotating motion. The rotating motion of the vortex rotor causes the refrigerant to be compressed and increase its temperature and pressure.

2. Condensation process: High-temperature and high-pressure refrigerant is discharged from the scroll compressor and enters the air-cooled radiator (condenser). In an air-cooled radiator, the refrigerant passes through the heat sink and transfers heat to the surrounding environment through fan blowing and convection heat transfer, causing the refrigerant to cool and condense into a liquid.

3. Expansion process: The condensed refrigerant liquid enters the expansion valve (throttle device), which controls the flow and pressure of the refrigerant. Through the throttling effect of the expansion valve, the pressure and temperature of the refrigerant are reduced, preparing to enter the evaporator.

4. Evaporation process: Refrigerant enters the evaporator and flows in the evaporator pipe inside the evaporator. In the evaporator, the refrigerant absorbs heat from the external environment, causing the refrigerant to change from a liquid state to a vapor state. This process absorbs heat from the surrounding environment, thereby achieving a cooling effect.

5. Cycle process: The refrigerant is discharged from the evaporator in the form of steam, and is sucked into the scroll compressor again. After cyclic processes such as compression, condensation, expansion and evaporation, the refrigerant is continuously circulated to achieve a continuous cooling effect.

Through the compression effect of the scroll compressor and the heat dissipation effect of the air-cooled radiator, the air-cooled scroll chiller can take away heat from the object or system to be cooled, and supply the cooled water to the equipment or equipment that needs to be cooled. process to achieve the cooling effect. The entire system continuously operates through the above-mentioned cycle process to maintain a stable cooling effect.

JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control

Techinical Parameters:

Model JLSF-30A JLSF-40A JLSF-50A JLSF-60A JLSF-70A JLSF-80A JLSF-90A JLSF-100A JLSF-110A
Cooling capacity KW/h 94.8 126.4 158.0 189.6 221.2 252.8 284.4 316.0 347.6
Kcal/h 84,000 112,000 140,000 168,000 196,000 224,000 252,000 280,000 308,000
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415V 50HZ/60HZ
Total power KW 24.8 33.7 41.5 45.2 57.4 62 69 72.5 83.6
Running current A 41 56.5 69.6 75.9 96.5 86.7 116.2 122 111.3
Chilled water m³/h 15 19.6 24.2 29 35 40 45 50.2 53.8
compressor type Semi-hermetic screw type
Start method Y-△
capacity adjustment 0,25,50,75,100
input power KW 23.3 30.7 38.5 42.2 51.4 56 63 66.3 73
Frozen oil type HBR-A01
filling volume L 7 7 8 12 16 16 16 16 18
refrigerant type R-22/R407C
control method Temperature Sensing External Pressure Equalizing Expansion Valve
Evaporator filling volume KG 16 22 27 32 36 42 46 52 56
type shell and tube
condenser Diameter mm DN65 DN80 DN80 DN80 DN80 DN100 DN100 DN100 DN125
type High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan
Cooling air volume m³/h 28000 36000 45000 5500 63000 74000 83000 92000 102000
protective device High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Dimensions L mm 2200 2300 2500 2800 2800 2910 3100 3150 3150
W mm 1100 1100 1200 1200 1800 2050 2050 2050 2050
H mm 1820 2030 2030 2030 2100 2100 2100 2100 2100
weight KG 920 1120 1350 1560 1780 1920 2230 2450 2720

Model JLSF-120D JLSF-130A JLSF-150A JLSF-160D JLSF-180D JLSF-200D JLSF-240D JLSF-260D JLSF-300D
Cooling capacity KW/h 379.2 410.8 474.0 505.6 568.8 632.0 758.4 821.6 948.0
Kcal/h 336,000 364,000 420,000 448,000 504,000 560,000 672,000 728,000 840,000
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415V 50HZ/60HZ
Total power KW 149 169 195.1 204.8 240 247.5 282 309.4 364.5
Running current A 88.6 100.5 114.8 120.5 141.6 145.6 165.5 182 214.4
Chilled water m³/h 59 65 74 79 90 101 119 130 152
compressor type Semi-hermetic screw type
Start method Y-△
capacity adjustment 0,25,50,75,100
input power KW 79.6 88.5 102.8 108.5 126.6 130.6 150.5 167 199.4
Frozen oil type HBR-A01
filling volume L 18 18 23 24 24 28 32 32 36
refrigerant type R-22/R407C
control method Temperature Sensing External Pressure Equalizing Expansion Valve
Evaporator filling volume KG 62 66 75 80 92 103 121 126 150
type shell and tube
condenser Diameter mm DN1250 DN150 DN200
type High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan
Cooling air volume m³/h 112000 122000 141000 150000 169000 189000 223000 245000 285000
protective device High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Dimensions L mm 3500 3800 4120 4250 4680 4680 5230 5630 6550
W mm 2100 2100 2100 2100 2100 2100 2100 2100 2210
H mm 2120 2120 2120 2120 2120 2120 2120 2120 2150
weight KG 3050 3360 3670 3550 4120 4230 4650 5570 7420


Application Industry:


Air-cooled scroll chillers are suitable for the following places:

1. Industrial production workshop: Air-cooled scroll chillers can provide cooling for various industrial production processes, such as laser cutting, stamping, plastic injection molding, electronic assembly, etc. They are suitable for industrial production environments that require large amounts of cooling capacity and stable performance.

2. Commercial offices: Air-cooled scroll chillers can provide cooling water sources for central air conditioning systems in commercial buildings. They can be used in places such as office buildings, shopping malls, hotels, hospitals and schools to provide efficient cooling capacity for large air conditioning systems.

3. Electronic equipment and communication equipment rooms: The operation of electronic equipment and communication equipment will generate a large amount of heat and requires cooling to maintain the normal operation of the equipment. Air-cooled scroll chillers can provide reliable cooling effects for electronic equipment and communication equipment rooms, ensuring the stability and reliability of the equipment.

4. Stadiums and theaters: Large stadiums and theaters usually require strong cooling capacity to meet the comfort requirements of crowded places. Air-cooled scroll chillers can provide efficient air conditioning and refrigeration in these places to ensure the comfort of audiences and actors.

5. Power equipment and substations: Power equipment and substations generate a large amount of heat during operation and require cooling to maintain normal operation of the equipment. Air-cooled scroll chillers can provide reliable cooling for power equipment and substations, ensuring the stability and reliability of the equipment.

The appropriate air-cooled scroll chiller needs to be selected based on specific application requirements and environmental conditions. The best model and size can be determined based on cooling needs and system capacity, ensuring the chiller can meet the cooling requirements of the site.

JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control JLSF-75D Industrial Air Cooled Screw Chiller With Microcomputer Control

Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry

Upport and Services:


Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

Packing and Shipping:


Chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

What are the different ways to configure the chiller in the canning machine?


In the canning machinery, the configuration of the chiller can be different according to the specific needs and the characteristics of the mechanical equipment. The following are several common configuration methods:

1. Direct cooling: In the direct cooling configuration, the chiller directly transfers the cooling water to the parts or products that need to be cooled through the cooler or cooling pipes. This configuration is suitable for situations where rapid cooling is required, such as direct cooling of tanks, bottled water or other products.

2. Indirect cooling: In the indirect cooling configuration, the chiller passes the cooling water to an intermediate heat exchanger or cooler through the cooling circulation system, and then transfers the cooling medium to the parts that need to be cooled in the canning machinery or product. This can achieve better control and regulation of the cooling temperature, which is suitable for situations with stricter temperature requirements.

3. Cooling Tower: A cooling tower is another common cooling configuration. In this configuration, the chiller transfers heat to the air in the atmosphere through the cooling tower to achieve the cooling effect. Cooling towers are often used to handle large amounts of heat, such as in high-speed canning lines, where cooling towers can provide additional cooling capacity to keep the equipment running.

4. Combination of multiple chillers: For large-scale canning production lines or situations that require higher cooling capacity, multiple chillers can be combined. Multiple chillers can be configured in parallel or in series to provide greater cooling capacity and greater flexibility. This configuration method can be expanded and adjusted according to actual needs to meet different production requirements.

It should be noted that the specific chiller configuration method should be evaluated and selected according to the type of canning machinery, process requirements and cooling needs. When configuring a chiller, it is recommended to have a detailed discussion with the equipment manufacturer or a professional engineer to ensure the best cooling effect and system performance.