Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Water Cooled Screw Chiller /

JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge

Contact Now
Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrJlschiller
Contact Now

JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge

Ask Latest Price
Video Channel
Brand Name :JIALIS
Model Number :JLSW-70D
Certification :CE/ISO9001
Place of Origin :Dongguan China
MOQ :1 set
Price :Discuss
Payment Terms :T/T
Supply Ability :100 units per month
Delivery Time :20 days
Packaging Details :Plywood wooden box
Product Name :Water Cooled Screw Chiller
Compressor Type :Screw Compressor
Compressor Brand :Hanbell
Cooling Capacity :100-1000kW
Control System :PLC
Controller :Microprocessor Control
Evaporator :Shell and Tube
Condenser :Shell and Tube
Noise Level :Low noise
Protection :High/Low Pressure, Phase Reversal, Overload, Overheat, etc.
Refrigerant :R22/R407C/R134a
Voltage :380V/3N/50Hz
Warranty :1 Year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

JLSW-70D Water Cooled Screw Chiller MRI Equipment,CT Scanning Equipment,Refrigerated Centrifuge


Product Description:


Water-cooled screw chiller is a kind of refrigeration equipment for industrial use, mainly used to provide cooling and air conditioning services for large buildings such as factories, commercial centers, and office buildings. It lowers the temperature of water by circulating refrigerant, so that cold water is delivered to the area that needs to be cooled to achieve the effect of cooling, dehumidification and keeping the air fresh.

The main components of a water-cooled screw chiller are compressors, condensers, evaporators, and throttle valves. Among them, the screw compressor is the core part of the whole system, which increases its temperature and pressure by compressing the refrigerant, makes it dissipate heat in the condenser and cools it down, and then absorbs heat in the evaporator and lowers the temperature, forming cold water recirculation use.

The water-cooled screw chiller has the characteristics of high cooling efficiency, large cooling capacity, stable operation, low noise, and easy maintenance. It is suitable for places that require a lot of cooling, such as large buildings and industrial manufacturing enterprises. However, its installation and use costs are high, and it requires a large space and power energy support, so it is generally used for large-scale projects and commercial purposes.


Production Features:


Water-cooled screw chiller has the following characteristics:

1.High refrigeration efficiency: The water-cooled screw chiller uses a screw compressor, which has the advantages of high efficiency, low noise, low vibration, and good stability. It can quickly cool down and meet large-scale refrigeration needs.

2.Large refrigerating capacity: The water-cooled screw chiller has a large refrigerating capacity and is suitable for places requiring a large amount of cooling, such as large buildings and industrial manufacturing enterprises.

3.Good stability: The key components such as the compressor, condenser and evaporator of the water-cooled screw chiller are made of high-quality materials, with high durability and stability, and can run stably for a long time.

4.Simple maintenance: The maintenance of the water-cooled screw chiller is relatively simple. It only needs basic maintenance such as regular cleaning, inspection and filter replacement to maintain its normal operation.

5.Environmental protection and energy saving: The water-cooled screw chiller uses environmentally friendly refrigerants and has a high energy efficiency ratio. At the same time, it can realize energy saving and environmental protection benefits through linkage control with other systems.

6.Strong adaptability: The water-cooled screw chiller can be combined in various forms according to the needs to meet the refrigeration requirements of different occasions and different needs. It is a highly flexible refrigeration equipment.

Working Principle:


The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.


2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.


3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.


4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.


Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge

Techinical Parameters:

Model JLSW-30D JLSW-40D JLSW-50D JLSW-60D JLSW-80D JLSW-100D JLSW-120D JLSW-150D
Cooling capacity KW/h 100 140 180 200 260 370 430 550
TR 28.5 39.8 51.2 56.9 73.9 105.2 122.3 156.4
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
Compressor Type Semi-hermetic screw
Power KW 22 30 36 41 56 80 93 118
electric current A 39 51 65 71 95 135 156 198
Refrigerant Type R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 16.5 22.2 27.5 33.4 44.4 55.6 66.5 82.6
Evaporator shell and tube
Flow m³/h 17.2 22.4 29.3 33 43.9 64.2 75.2 95.3
Diameter inch G2.5" G3" G3" G3" G3" G4" G4" G4"
Compressor Type shell and tube
Flow m³/h 22.4 29.2 35.2 42.9 57.8 84.3 101.1 123.9
Diameter inch G2.5" G3" G3" G3" G3" G4" G4" G4"
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 2200 2250 2350 2450 2500 2900 3000 3000
W mm 800 800 800 900 900 900 1500 1500
H mm 1500 1600 1650 1750 1800 1850 1500 1550
Unit weight Kg 960 990 1260 1380 1520 1830 2150 2580

Model JLSW-170D JLSW-200D JLSW-230D JLSW-260D JLSW-280D JLSW-310D JLSW-350D JLSW-400D
Cooling capacity KW/h 620 710 830 930 1020 1130 1270 1530
TR 176.3 201.9 236 264.4 290 321.3 361.1 435
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
Compressor Type Semi-hermetic screw
Power KW 130 150 175 200 225 250 281 325
electric current A 218 253 295 335 390 432 480 553
Refrigerant Type R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 93.8 111.2 126.8 144.1 155.4 170.9 193.2 220.9
Evaporator shell and tube
Flow m³/h 108.6 126.3 144.9 163.8 176.4 196.5 222.4 252.6
Diameter inch G5" G5" G6" G6" G8" G8" G8" G8"
Compressor Type shell and tube
Flow m³/h 141.1 166.2 190.9 215.8 232.4 258.6 290.8 333.2
Diameter inch G5" G5" G6" G6" G8" G8" G8" G8"
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 3600 3600 3600 3650 3650 3700 3700 4200
W mm 1500 1500 1500 1600 1650 1750 1750 1750
H mm 1650 1650 1700 1700 1700 1750 1800 1800
Unit weight Kg 3050 3200 3450 3780 4060 4330 4600 4820


Application Industry:


There are many devices in medical laboratories and medical equipment that require chillers to provide refrigeration and cooling functions. The following are some commonly used medical laboratories and medical equipment that require chillers:

1.Magnetic resonance imaging equipment (MRI): MRI equipment needs to use cooling water in the refrigerant circulation system to reduce the temperature to ensure the normal operation of the equipment.

2.CT scanning equipment: CT scanning equipment needs to use cooling water to reduce the temperature of the X-ray tube to ensure the normal operation of the equipment.

3.Chemical analysis instruments: In medical laboratories, many chemical analysis instruments need to use cooling water to reduce the temperature inside the instrument to ensure the accuracy and stability of the instrument.

4.Refrigerated centrifuges: Refrigerated centrifuges need to use refrigerant to cool the centrifuge tubes and rotors of the centrifuge to ensure the stability and accuracy of the samples in the experiment.

5.Medical cold therapy equipment: Medical cold therapy equipment needs to use cooling water to lower the temperature inside the device to produce cold therapy effects such as pain relief and swelling reduction.

In short, chillers play an important role in medical laboratories and medical equipment, which can provide refrigeration and cooling functions to ensure the normal operation of equipment and the accuracy of experimental results.

JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge JLSW-70D Water Cooled Industrial Chiller For MRI Equipment Refrigerated Centrifuge

Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

Precautions for the use of medical chillers?


Medical chillers are one of the commonly used refrigeration equipment in medical equipment. In order to ensure the normal operation and safe use of medical chillers, the following are some precautions for use:

1.Installation location: The medical chiller should be installed in a dry, ventilated, dust-free, non-corrosive gas and suitable temperature place.

2.Power wiring: The power wiring of the medical chiller should comply with national standards and manufacturer's regulations. Do not change it at will, so as not to cause electrical failure or safety accident.

3.Cooling water pipeline: The cooling water pipeline of the medical chiller should be installed correctly, and the interface should be fastened to prevent leakage. Check whether the waterway is unobstructed before use.

4.Maintenance: The medical chiller should be cleaned, disinfected and maintained regularly to ensure the normal operation and service life of the equipment.

5.Temperature control: The medical chiller should be adjusted according to the required temperature setting to ensure the stability of the cooling water.

6.Safe operation: The medical chiller should pay attention to safe operation during use to prevent equipment failure or accidents.

7.Prevention of overload: The medical chiller should avoid overload operation during use, so as not to affect the life and use effect of the equipment.

In short, the correct use of medical chillers can ensure the normal operation of medical equipment and improve the quality and efficiency of medical services. When using, you should pay attention to the above points to ensure the safety and reliability of the medical chiller.

Inquiry Cart 0