Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Water Cooled Screw Chiller /

JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz

Contact Now
Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrJlschiller
Contact Now

JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz

Ask Latest Price
Video Channel
Brand Name :JIALIS
Model Number :JLSW-110D
Certification :CE/ISO9001
Place of Origin :Dongguan China
MOQ :1 set
Price :Discuss
Payment Terms :T/T
Supply Ability :100 units per month
Delivery Time :20 days
Packaging Details :Plywood wooden box
Product Name :Water Cooled Screw Chiller
Cooling Temperature :5℃-35℃
Compressor Type :Screw Compressor
Compressor Brand :Hanbell
Cooling Capacity :100-1000kW
Control System :PLC
Controller :Microprocessor Control
Evaporator :Shell and Tube
Condenser :Shell and Tube
Noise Level :≤75dB(A)
Protection :Compressor Overload, High/Low Pressure, Water Flow, Phase Sequence, Anti-freezing
Refrigerant :R22/R407C/R134A/R410A
Voltage :380V/3N/50Hz
Power Supply :380V/3N/50Hz
Warranty :1 Year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

JLSW-110D Water Cooled Screw Chiller Food Processing Equipment, Cold Storage And Beverage Production Lines


Product Description:


Water-cooled screw chiller is a kind of refrigeration equipment for industrial use, mainly used to provide cooling and air conditioning services for large buildings such as factories, commercial centers, and office buildings. It lowers the temperature of water by circulating refrigerant, so that cold water is delivered to the area that needs to be cooled to achieve the effect of cooling, dehumidification and keeping the air fresh.

The main components of a water-cooled screw chiller are compressors, condensers, evaporators, and throttle valves. Among them, the screw compressor is the core part of the whole system, which increases its temperature and pressure by compressing the refrigerant, makes it dissipate heat in the condenser and cools it down, and then absorbs heat in the evaporator and lowers the temperature, forming cold water recirculation use.

The water-cooled screw chiller has the characteristics of high cooling efficiency, large cooling capacity, stable operation, low noise, and easy maintenance. It is suitable for places that require a lot of cooling, such as large buildings and industrial manufacturing enterprises. However, its installation and use costs are high, and it requires a large space and power energy support, so it is generally used for large-scale projects and commercial purposes.


Production Features:


Advantages of water-cooled screw chillers:

1. Heat dissipation efficiency: The water-cooled screw chiller transfers heat to the cooling water through the water cooler, and then discharges the heat through the cooling water circulation system. Due to the higher specific heat capacity of water, water cooling usually has higher heat dissipation efficiency and can remove heat more effectively.

2. System stability: The water cooling system is more stable than the air cooling system. The water-cooled screw chiller can provide a stable cooling water temperature through the water circulation system, and is not sensitive to changes in ambient temperature and humidity. This makes water-cooled systems more suitable for long-running and temperature-controlled applications.

3. Quiet operation: Water-cooled screw chillers are generally quieter than air-cooled chillers. Since the heat dissipation part of the water cooling system is located outdoors, the impact of noise on the indoor environment is small, and it is suitable for places with high noise requirements.

Working Principle:


The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.


2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.


3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.


4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.


Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz

Techinical Parameters:

Model JLSW-30D JLSW-40D JLSW-50D JLSW-60D JLSW-80D JLSW-100D JLSW-120D JLSW-150D
Cooling capacity KW/h 100 140 180 200 260 370 430 550
TR 28.5 39.8 51.2 56.9 73.9 105.2 122.3 156.4
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
Compressor Type Semi-hermetic screw
Power KW 22 30 36 41 56 80 93 118
electric current A 39 51 65 71 95 135 156 198
Refrigerant Type R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 16.5 22.2 27.5 33.4 44.4 55.6 66.5 82.6
Evaporator shell and tube
Flow m³/h 17.2 22.4 29.3 33 43.9 64.2 75.2 95.3
Diameter inch G2.5" G3" G3" G3" G3" G4" G4" G4"
Compressor Type shell and tube
Flow m³/h 22.4 29.2 35.2 42.9 57.8 84.3 101.1 123.9
Diameter inch G2.5" G3" G3" G3" G3" G4" G4" G4"
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 2200 2250 2350 2450 2500 2900 3000 3000
W mm 800 800 800 900 900 900 1500 1500
H mm 1500 1600 1650 1750 1800 1850 1500 1550
Unit weight Kg 960 990 1260 1380 1520 1830 2150 2580

Model JLSW-170D JLSW-200D JLSW-230D JLSW-260D JLSW-280D JLSW-310D JLSW-350D JLSW-400D
Cooling capacity KW/h 620 710 830 930 1020 1130 1270 1530
TR 176.3 201.9 236 264.4 290 321.3 361.1 435
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
Compressor Type Semi-hermetic screw
Power KW 130 150 175 200 225 250 281 325
electric current A 218 253 295 335 390 432 480 553
Refrigerant Type R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 93.8 111.2 126.8 144.1 155.4 170.9 193.2 220.9
Evaporator shell and tube
Flow m³/h 108.6 126.3 144.9 163.8 176.4 196.5 222.4 252.6
Diameter inch G5" G5" G6" G6" G8" G8" G8" G8"
Compressor Type shell and tube
Flow m³/h 141.1 166.2 190.9 215.8 232.4 258.6 290.8 333.2
Diameter inch G5" G5" G6" G6" G8" G8" G8" G8"
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 3600 3600 3600 3650 3650 3700 3700 4200
W mm 1500 1500 1500 1600 1650 1750 1750 1750
H mm 1650 1650 1700 1700 1700 1750 1800 1800
Unit weight Kg 3050 3200 3450 3780 4060 4330 4600 4820


Application Industry:


Water-cooled screw chiller is a kind of refrigeration equipment widely used in industrial and commercial fields. Its main application scenarios include:

1.Industrial refrigeration: Water-cooled screw chillers can be used in the field of industrial refrigeration, such as in the production and processing of chemical, pharmaceutical, food, beverage and other industries, to cool or refrigerate equipment and materials.

2.Commercial air-conditioning: Water-cooled screw chillers can be used in commercial air-conditioning fields, such as shopping malls, office buildings, hotels, cinemas and other places, to provide cooling and heating services.

3.Medical field: Water-cooled screw chillers can be used in the medical field, such as temperature and humidity control in hospital operating rooms, drug storage rooms and other places.

4.Manufacturing industry: Water-cooled screw chillers can be used in manufacturing fields, such as semiconductor, electronics, machinery and other industries, to cool or refrigerate equipment and materials during production and processing.

In short, water-cooled screw chillers are suitable for a variety of refrigeration demand scenarios, including industrial refrigeration, commercial air conditioning, medical fields, and manufacturing industries, providing users with efficient and reliable refrigeration services.

JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz JLSW-110D PLC Water Chiller For Food Processing Cold Storage 380V 50Hz

Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

What is the difference in the life of a water-cooled screw chiller and an air-cooled chiller?


The life of water-cooled screw chillers and air-cooled chillers depends on many factors, including manufacturing quality, maintenance, operating environment and usage. In general, water-cooled screw chillers can last longer than air-cooled chillers with normal use and proper maintenance. This is because the water cooling system has some advantages, such as better heat dissipation efficiency and stability, which can reduce the load and loss on the equipment.

The following are some differences between water-cooled screw chillers and air-cooled chillers in terms of life:

1. Radiator: The radiator of a water-cooled screw chiller usually adopts a spiral plate or pipe structure, which can dissipate heat more effectively due to the high specific heat capacity and heat transfer efficiency of water. The radiator of the air-cooled chiller relies on the cooling effect of the air on the surface of the radiator. Due to the higher heat dissipation efficiency of the water cooling method, the life of the radiator in the water-cooled screw chiller may be relatively longer.

2. Cleaning and maintenance: Water-cooled screw chillers require regular inspection and maintenance of the cooling water circulation system to prevent scale and corrosion problems. Inadequate water quality or lack of proper maintenance can result in damage to radiators and other components. In contrast, air-cooled chillers are relatively simple to maintain, requiring only regular cleaning of the air filter and radiator surfaces.

3. Environmental factors: Water-cooled screw chillers have high requirements on the environment and require a stable water source and drainage system. If the water quality is poor or there are problems with the water circulation system, it may adversely affect the life of the equipment. The air-cooled chiller has lower environmental requirements and is suitable for various environmental conditions, but may be affected by factors such as temperature and humidity.

It should be emphasized that whether it is a water-cooled screw chiller or an air-cooled chiller, correct installation, regular maintenance and proper use are crucial factors for extending the life of the equipment. Regular maintenance and attention to usage conditions can help ensure the proper operation and longevity of your chiller.

Inquiry Cart 0