Add to Cart
JLSW-40D Water Cooled Screw Chiller Cold Storage, Refrigeration Equipment, Freeze Drying Equipment
Product Description:
Water-cooled screw chiller is a kind of refrigeration equipment for industrial use, mainly used to provide cooling and air conditioning services for large buildings such as factories, commercial centers, and office buildings. It lowers the temperature of water by circulating refrigerant, so that cold water is delivered to the area that needs to be cooled to achieve the effect of cooling, dehumidification and keeping the air fresh.
The main components of a water-cooled screw chiller are compressors, condensers, evaporators, and throttle valves. Among them, the screw compressor is the core part of the whole system, which increases its temperature and pressure by compressing the refrigerant, makes it dissipate heat in the condenser and cools it down, and then absorbs heat in the evaporator and lowers the temperature, forming cold water recirculation use.
The water-cooled screw chiller has the characteristics of high cooling efficiency, large cooling capacity, stable operation, low noise, and easy maintenance. It is suitable for places that require a lot of cooling, such as large buildings and industrial manufacturing enterprises. However, its installation and use costs are high, and it requires a large space and power energy support, so it is generally used for large-scale projects and commercial purposes.
Production Features:
Screw compressors have some unique advantages and disadvantages compared to other types of compressors, here are some common comparisons:
Advantage:
1. High-efficiency capability: Screw compressors perform well in energy conversion, have high-efficiency energy conversion capabilities, can provide high cooling capacity, and show advantages in energy consumption.
2. Wide working range: The screw compressor has a wide working range, can run stably under different load conditions, and can automatically adjust the cooling capacity to meet actual needs.
3. Low vibration and noise: The structural design of the screw compressor makes the vibration and noise low during operation. Compared with other types of compressors, the working process is relatively stable, which reduces the interference of the machine on the surrounding environment.
4. High reliability and durability: Screw compressors usually use high-quality materials and manufacturing processes, have high reliability and durability, can run stably for a long time, and require less maintenance and repairs.
Disadvantages:
1. Large size and weight: Compared to some other types of compressors, screw compressors are large in size and weight. This can present some challenges with installation and space requirements.
2. High initial cost: The initial cost of a screw compressor is usually high due to its complicated structure and manufacturing process. In the long run, however, its high-efficiency capabilities can lead to savings in operating costs.
3. Part load efficiency: The efficiency of screw compressors may decrease at part load conditions. Under low or varying load conditions, supplementary measures may be required to improve efficiency.
It is important to note that advantages and disadvantages will vary depending on the specific application and conditions of use. When choosing a compressor, factors such as actual needs, performance requirements, and cost-effectiveness should be considered comprehensively, and detailed consultation with manufacturers or professionals should be conducted.
Working Principle:
The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.
2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.
3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.
4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.
Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.
Techinical Parameters:
Model | JLSW-30D | JLSW-40D | JLSW-50D | JLSW-60D | JLSW-80D | JLSW-100D | JLSW-120D | JLSW-150D | ||
Cooling capacity | KW/h | 100 | 140 | 180 | 200 | 260 | 370 | 430 | 550 | |
TR | 28.5 | 39.8 | 51.2 | 56.9 | 73.9 | 105.2 | 122.3 | 156.4 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | |||||||||
Power supply | 3N-380V/415 50HZ/60HZ | |||||||||
Compressor | Type | Semi-hermetic screw | ||||||||
Power | KW | 22 | 30 | 36 | 41 | 56 | 80 | 93 | 118 | |
electric current | A | 39 | 51 | 65 | 71 | 95 | 135 | 156 | 198 | |
Refrigerant | Type | R22/R407c | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 16.5 | 22.2 | 27.5 | 33.4 | 44.4 | 55.6 | 66.5 | 82.6 | |
Evaporator | shell and tube | |||||||||
Flow | m³/h | 17.2 | 22.4 | 29.3 | 33 | 43.9 | 64.2 | 75.2 | 95.3 | |
Diameter | inch | G2.5" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | |
Compressor | Type | shell and tube | ||||||||
Flow | m³/h | 22.4 | 29.2 | 35.2 | 42.9 | 57.8 | 84.3 | 101.1 | 123.9 | |
Diameter | inch | G2.5" | G3" | G3" | G3" | G3" | G4" | G4" | G4" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 2200 | 2250 | 2350 | 2450 | 2500 | 2900 | 3000 | 3000 |
W | mm | 800 | 800 | 800 | 900 | 900 | 900 | 1500 | 1500 | |
H | mm | 1500 | 1600 | 1650 | 1750 | 1800 | 1850 | 1500 | 1550 | |
Unit weight | Kg | 960 | 990 | 1260 | 1380 | 1520 | 1830 | 2150 | 2580 |
Model | JLSW-170D | JLSW-200D | JLSW-230D | JLSW-260D | JLSW-280D | JLSW-310D | JLSW-350D | JLSW-400D | ||
Cooling capacity | KW/h | 620 | 710 | 830 | 930 | 1020 | 1130 | 1270 | 1530 | |
TR | 176.3 | 201.9 | 236 | 264.4 | 290 | 321.3 | 361.1 | 435 | ||
Temperature range | 5℃~35℃(Below 0℃ can be customized) | |||||||||
Power supply | 3N-380V/415 50HZ/60HZ | |||||||||
Compressor | Type | Semi-hermetic screw | ||||||||
Power | KW | 130 | 150 | 175 | 200 | 225 | 250 | 281 | 325 | |
electric current | A | 218 | 253 | 295 | 335 | 390 | 432 | 480 | 553 | |
Refrigerant | Type | R22/R407c | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 93.8 | 111.2 | 126.8 | 144.1 | 155.4 | 170.9 | 193.2 | 220.9 | |
Evaporator | shell and tube | |||||||||
Flow | m³/h | 108.6 | 126.3 | 144.9 | 163.8 | 176.4 | 196.5 | 222.4 | 252.6 | |
Diameter | inch | G5" | G5" | G6" | G6" | G8" | G8" | G8" | G8" | |
Compressor | Type | shell and tube | ||||||||
Flow | m³/h | 141.1 | 166.2 | 190.9 | 215.8 | 232.4 | 258.6 | 290.8 | 333.2 | |
Diameter | inch | G5" | G5" | G6" | G6" | G8" | G8" | G8" | G8" | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 3600 | 3600 | 3600 | 3650 | 3650 | 3700 | 3700 | 4200 |
W | mm | 1500 | 1500 | 1500 | 1600 | 1650 | 1750 | 1750 | 1750 | |
H | mm | 1650 | 1650 | 1700 | 1700 | 1700 | 1750 | 1800 | 1800 | |
Unit weight | Kg | 3050 | 3200 | 3450 | 3780 | 4060 | 4330 | 4600 | 4820 |
Application Industry:
Water-cooled screw chiller is a kind of refrigeration equipment widely used in industrial and commercial fields. Its main application scenarios include:
1.Industrial refrigeration: Water-cooled screw chillers can be used in the field of industrial refrigeration, such as in the production and processing of chemical, pharmaceutical, food, beverage and other industries, to cool or refrigerate equipment and materials.
2.Commercial air-conditioning: Water-cooled screw chillers can be used in commercial air-conditioning fields, such as shopping malls, office buildings, hotels, cinemas and other places, to provide cooling and heating services.
3.Medical field: Water-cooled screw chillers can be used in the medical field, such as temperature and humidity control in hospital operating rooms, drug storage rooms and other places.
4.Manufacturing industry: Water-cooled screw chillers can be used in manufacturing fields, such as semiconductor, electronics, machinery and other industries, to cool or refrigerate equipment and materials during production and processing.
In short, water-cooled screw chillers are suitable for a variety of refrigeration demand scenarios, including industrial refrigeration, commercial air conditioning, medical fields, and manufacturing industries, providing users with efficient and reliable refrigeration services.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
What is the energy efficiency of screw compressor?
Screw compressors generally have high energy efficiency. The following are some factors related to the energy efficiency of screw compressors:
1. Efficient design: The design of the screw compressor has been carefully optimized to improve energy conversion efficiency. They usually feature highly efficient screw shafts and gas enclosure systems to minimize energy loss.
2. Wide working range: The screw compressor can maintain high energy efficiency under different load conditions. They have a wide operating range and can automatically adjust operating parameters according to actual needs to provide the best energy efficiency performance.
3. Variable frequency drive: Screw compressors are usually combined with a variable frequency drive, which can adjust the operating speed according to the actual load demand. This variable frequency control can effectively reduce energy consumption, especially at low or partial load conditions to achieve higher energy efficiency.
4. Operation control: Screw compressors are usually equipped with an advanced operation control system, which can monitor and adjust operating parameters in real time to ensure the best energy efficiency performance. For example, through intelligent control algorithms and sensors, load matching, pressure control and energy-saving operation can be realized.
5. Maintenance and maintenance: Regular maintenance and maintenance are essential to maintain the energy efficiency of the screw compressor. Cleaning of components such as heat exchangers, filters and cooling systems, as well as regular inspection and calibration of control systems, can ensure efficient operation of screw compressors.
It should be noted that the specific screw compressor energy efficiency is also affected by many factors, including the model and specification of the compressor, operating conditions, load requirements, and ambient temperature. When selecting and using a screw compressor, it should be evaluated according to actual needs, and consult with the manufacturer or professionals to ensure the best energy efficiency performance.