Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Explosion Proof Water Chiller /

JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry

Contact Now
Dongguan Jialisheng Refrigeration Equipment Co., Ltd.
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrJlschiller
Contact Now

JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry

Ask Latest Price
Video Channel
Brand Name :JIALIS
Model Number :JLSF-60AD
Certification :CE/ISO
Place of Origin :Dongguan China
MOQ :1 set
Price :Discuss
Payment Terms :T/T
Supply Ability :50 units per month
Delivery Time :20 days
Packaging Details :Plywood wooden box
Product Name :Air Cooled Explosion-Proof Screw Chiller
Compressor Type :Screw
Evaporator :Shell and Tube
Condenser :Finned
Control System :PLC
Controller :Microprocessor
Noise Level :≤65dB(A)
Protection Level :IP54
Refrigerant :R22/R407C
Temperature Range :0-50℃
Protection :High/Low Pressure, Overload, Phase Sequence, Anti-Freezing
Warranty :1 Year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

JLSF-60AD Air Cooled Explosion-Proof Screw Chiller Chemical Industry Oil Field Medical Treatment

Product Description:


The air-cooled explosion-proof screw chiller is a screw chiller that adopts an air-cooled cooling method and has explosion-proof performance. It is mainly composed of a compressor, a condenser, an evaporator, a fan, an electric control system, etc. The heat is emitted to the surrounding air through the fan, and the change of the refrigerant in the cycle realizes the purpose of cooling and cooling without an additional water circulation system, saving energy. Water resources, also reduces the cost of water treatment, but also improves the cooling efficiency of the equipment.


Production Features:


Compared with ordinary screw chillers, air-cooled explosion-proof screw chillers have the following characteristics:

1.Explosion-proof safety: It adopts explosion-proof design with safety guarantee, and is suitable for occasions with high safety requirements.

2.High efficiency and energy saving: Air-cooled cooling method is adopted, no additional water circulation system is required, water resources are saved, water treatment costs are reduced, and the cooling efficiency of the equipment is also improved.

3.Environmental protection and energy saving: the use of environmentally friendly refrigerants will not pollute the environment, and at the same time achieve the purpose of energy saving.

4.Easy to operate: It has an intelligent control system, which can realize automatic and intelligent operation and control, and is easy to operate.

5.Wide range of applications: Air-cooled explosion-proof screw chillers can be used in many industries, such as chemical, oil field, medical and other industries, and have broad application prospects.

In short, the air-cooled explosion-proof screw chiller is a safe, reliable, energy-efficient, environmentally friendly, energy-saving, and easy-to-operate refrigeration equipment, which has a wide range of application prospects.

Working Principle:


The working principle of the air-cooled explosion-proof screw chiller is:
1.The compressor sucks in low-temperature and low-pressure refrigerant and compresses it into a high-temperature and high-pressure gas.

2.The high-temperature and high-pressure gas enters the condenser, releases heat into the air through the radiator, and turns into a high-temperature and high-pressure liquid.

3.The high-temperature and high-pressure liquid enters the evaporator, exchanges heat with the outside through the evaporator, and turns into low-temperature and low-pressure steam.

4.The low-temperature and low-pressure steam enters the compressor again, and the cycle repeats.

JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry

Techinical Parameters:

Model

JLSF-

30AD

JLSF-

40AD

JLSF-

50AD

JLSF-

60AD

JLSF-

70AD

JLSF-

80AD

JLSF-

90AD

JLSF-

100AD

JLSF-

110AD

Cooling capacity KW/h 94.8 126.4 158.0 189.6 221.2 252.8 284.4 316.0 347.6
TR 84,000 112,000 140,000 168,000 196,000 224,000 252,000 280,000 308,000
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415V 50HZ/60HZ
Total power KW 24.8 33.7 41.5 45.2 57.4 62 69 72.5 83.6
Running current A 41 56.5 69.6 75.9 96.5 86.7 116.2 122 111.3
Chilled water m³/h 15 19.6 24.2 29 35 40 45 50.2 53.8
compressor type Semi-hermetic screw type
Start method Y-△
capacity adjustment 0,25,50,75,100
input power KW 23.3 30.7 38.5 42.2 51.4 56 63 66.3 73
Frozen oil type HBR-A01
filling volume L 7 7 8 12 16 16 16 16 18
refrigerant type R-22/R407C
control method Temperature Sensing External Pressure Equalizing Expansion Valve
Evaporator filling volume KG 16 22 27 32 36 42 46 52 56
type shell and tube
condenser Diameter mm DN65 DN80 DN80 DN80 DN80 DN100 DN100 DN100 DN125
type High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan
Cooling air volume m³/h 28000 36000 45000 5500 63000 74000 83000 92000 102000
protective device High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Dimensions L mm 2200 2300 2500 2800 2800 2910 3100 3150 3150
W mm 1100 1100 1200 1200 1800 2050 2050 2050 2050
H mm 1820 2030 2030 2030 2100 2100 2100 2100 2100
weight KG 920 1120 1350 1560 1780 1920 2230 2450 2720

Model JLSF-120AD

JLSF-

130AD

JLSF-150AD JLSF-160AD JLSF-180AD JLSF-200AD

JLSF-

240AD

JLSF-260AD JLSF-300AD
Cooling capacity KW/h 379.2 410.8 474.0 505.6 568.8 632.0 758.4 821.6 948.0
TR 336,000 364,000 420,000 448,000 504,000 560,000 672,000 728,000 840,000
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415V 50HZ/60HZ
Total power KW 149 169 195.1 204.8 240 247.5 282 309.4 364.5
Running current A 88.6 100.5 114.8 120.5 141.6 145.6 165.5 182 214.4
Chilled water m³/h 59 65 74 79 90 101 119 130 152
compressor type Semi-hermetic screw type
Start method Y-△
capacity adjustment 0,25,50,75,100
input power KW 79.6 88.5 102.8 108.5 126.6 130.6 150.5 167 199.4
Frozen oil type HBR-A01
filling volume L 18 18 23 24 24 28 32 32 36
refrigerant type R-22/R407C
control method Temperature Sensing External Pressure Equalizing Expansion Valve
Evaporator filling volume KG 62 66 75 80 92 103 121 126 150
type shell and tube
condenser Diameter mm DN1250 DN150 DN200
type High-efficiency copper-sleeved aluminum-fin type + low-noise external rotor fan
Cooling air volume m³/h 112000 122000 141000 150000 169000 189000 223000 245000 285000
protective device High and low voltage switch, antifreeze protection, soluble plug, safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Dimensions L mm 3500 3800 4120 4250 4680 4680 5230 5630 6550
W mm 2100 2100 2100 2100 2100 2100 2100 2100 2210
H mm 2120 2120 2120 2120 2120 2120 2120 2120 2150
weight KG 3050 3360 3670 3550 4120 4230 4650 5570 7420


Application Industry:


The air-cooled explosion-proof screw chiller has the characteristics of explosion-proof performance and high efficiency and energy saving, and is suitable for industries with high safety requirements and refrigeration requirements. Here are some common application industries:

Chemical industry: The chemical industry has high requirements for refrigeration and also needs to ensure safety. Air-cooled explosion-proof screw chillers can meet these requirements and are widely used in cooling and refrigeration in chemical production processes.

Petrochemical industry: The production process of the petrochemical industry requires a large number of refrigeration equipment, but also needs to ensure safety. Air-cooled explosion-proof screw chillers can meet these needs and are widely used in the production process of the petrochemical industry.

Medical industry: The medical industry needs to ensure the safety and cooling effect of refrigeration equipment. Air-cooled explosion-proof screw chillers can meet these needs and are widely used in medical equipment, such as nuclear magnetic resonance equipment, CT machines, etc.

Electronics industry: The electronics industry also has relatively high refrigeration requirements. Air-cooled explosion-proof screw chillers can meet these requirements and are widely used in electronic equipment, such as semiconductor production equipment, electron microscopes, etc.

Automobile industry: The production process of the automobile industry also requires a large amount of refrigeration equipment. The air-cooled explosion-proof screw chiller can meet these needs and is widely used in cooling and refrigeration in the automobile production process.

In short, the air-cooled explosion-proof screw chiller is widely used and is suitable for industries that require high safety and cooling effects.

JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry JLSF-60AD Screw Air Cooled Chiller , Explosion Proof Chiller For Chemical Industry

Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

Maintenance Method:


For air-cooled explosion-proof screw chillers, regular maintenance is very important, which can prolong the service life of the equipment, improve the efficiency of the equipment, and reduce maintenance costs. Here are some common maintenance methods:

1.Clean the appearance and radiator regularly: Since the air-cooled explosion-proof screw chiller adopts air-cooling method to dissipate heat, it is very important to clean the appearance and radiator regularly to ensure the cooling effect and prevent the equipment from overheating.

2.Regular replacement of the filter element and refrigerant: Regular replacement of the filter element can ensure the quality and flow of the refrigerant and improve the cooling efficiency of the equipment. At the same time, regular inspection and replacement of refrigerant can also ensure the cooling effect of the equipment.

3.Regularly check the electrical system and transmission system: Regular inspection of the electrical system and transmission system can ensure the safety and operation stability of the equipment and avoid failures.

4.Regular inspection of compressors and condensers: regular inspections of compressors and condensers can ensure the cooling efficiency and operational stability of the equipment, and avoid failures.

5.Pay attention to the environment and ventilation conditions of the equipment: the operating environment and ventilation conditions of the equipment have a great impact on the service life and efficiency of the equipment, so pay attention to the environment and ventilation conditions around the equipment to ensure the normal operation of the equipment.

In short, the maintenance of the air-cooled explosion-proof screw chiller is very important, which can ensure the safety and operation stability of the equipment, prolong the service life of the equipment, improve the efficiency of the equipment, and reduce the maintenance cost.

Inquiry Cart 0