JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature

Ask Latest Price
Video Channel
Brand Name :JIALIS
Model Number :JLSF-62HP
Certification :CE/ISO9001
Place of Origin :Dongguan China
MOQ :1 set
Price :Discuss
Payment Terms :T/T
Supply Ability :300 units per month
Delivery Time :25 days
Packaging Details :Plywood wooden box
Product Name :Air Cooled Water Chiller
Highlights :Two chillers in one/Independent control of two systems
control system :2 PLC/Microcomputer
outlet water temperature :5-50℃
Compressor Type :Scroll/Semi-Hermetic/Hermetic
Evaporator :Water Tank Coil/Shell and Tube/Plate Heat Exchanger
condenser :Finned Tube
Condenser Fans :Axial/Centrifugal
noise level :≤75dB(A)
Voltage :220V/380V/415V/440V/480V
Frequency :50HZ/60HZ
Refrigerant :R22/R407C/R134A/R410A/R404A
protection system :High/Low Pressure, Water Flow, Overload, etc.
Pump :Centrifugal/vertical
Warranty :12 months
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

JLSF-62HP Air Cooled Water Chiller Low Temperature Or Constant Temperature Cooling Water


Product Description:


The two-system integrated chiller is a chiller with a double circulation system, which can provide cooling water for two different cooling systems at the same time.

Air-cooled chiller is a kind of chiller equipment, also known as chiller. It discharges heat by using an air condenser, so it is called "air-cooled", which is different from the way water-cooled chillers work, which uses a water condenser to discharge heat.

Compared with the traditional water-cooled chiller, the difference between the air-cooled chiller and the traditional water-cooled chiller is that it uses an air cooler as a condenser, and the fan blows the air required for heat dissipation from one side of the machine and exhausts it from the other side. Achieve cooling. Therefore, the air-cooled chiller does not need an external cooling water source, is independent, and is very convenient to install and move.




Product Features:


The advantages of the two-system integrated chiller include:

1.Double circulation system: Two-system integrated chiller has a double circulation system, which can provide cooling water for two different cooling systems at the same time, which improves the utilization rate of the equipment.

2.High efficiency and energy saving: The two-system integrated chiller adopts high-efficiency refrigeration technology and cooling water pump, which can realize energy saving and environmental protection, reduce energy consumption, and improve the energy efficiency ratio of the equipment.

3.Stable and reliable: The two-system integrated chiller has an independent refrigeration system and cooling system, which can ensure the stability and reliability of the equipment during operation.

4.High space utilization: The two-system integrated chiller has a compact design and takes up little space, which can meet the occasions with limited space.

5.Easy to operate: The two-system integrated chiller is easy to operate and easy to maintain, which can reduce maintenance costs and difficulty.

In short, the two-system integrated chiller is a chiller with a double circulation system, which can provide cooling water for two different cooling systems at the same time. It has the advantages of high efficiency, energy saving, stability and reliability, high space utilization, and easy operation. It is suitable for Occasions that need to provide cooling water for two different cooling systems at the same time, such as central air conditioning systems, cooling tower systems, industrial refrigeration systems, etc.

Working Principle:


The main components of an air-cooled chiller include a compressor, an air condenser, an expansion valve, and an evaporator. Here is a basic overview of its workflow:

1.The compressor takes in low-pressure, low-temperature refrigerant gas and compresses it into high-pressure, high-temperature gas.

2.This high-temperature, high-pressure refrigerant gas enters the air condenser, exchanges heat with the ambient air, and discharges heat to the environment, while the refrigerant condenses from a gaseous state to a liquid state.

3.The high-pressure refrigerant liquid passes through the expansion valve, the pressure suddenly drops, and it turns into a low-pressure and low-temperature refrigerant liquid.

4.The low-temperature and low-pressure refrigerant liquid enters the evaporator, absorbs indoor heat, evaporates into a gaseous state by itself, and the indoor temperature drops to achieve the purpose of refrigeration.

5.The refrigerant gas is sucked into the compressor again to complete a cycle.

The advantages of air-cooled chillers include simple installation, no need for cooling towers and cooling water pumps, and low maintenance costs. However, its efficiency is lower than that of water-cooled chillers, especially at high ambient temperatures, and its efficiency will be further reduced

JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature

① Compressor ⑤ Evaporator ⑨ Temperature sensor ⑬ Bypass valve
② Condenser ⑥ Ball valve ⑩ Water tank ⑭ Low voltage controller
③ Filter drier ⑦ Antifreeze switch ⑪ Water pump pressure gauge ⑮ High voltage controller
④ Expansion valve ⑧ Float switch ⑫ Water pump

⑯ Pressure relief valve

Techinical Parameters:

Model JLSF-1HP JLSF-2HP JLSF-3HP JLSF-4HP JLSF-5HP JLSF-6HP JLSF-8HP JLSF-10HP
Cooling capacity KW/h 3.1 6.2 9.3 12.4 15.5 18.6 24.8 31
Kcal/h 2,700 5,400 8,100 10,800 13,500 16,200 21,600 27,000
Temperature range 5℃-35℃(Below 0℃ can be customized)
Power supply 1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ
Total power KW 1.21 2.03 2.84 3.7 4.5 5.7 7.33 8.83
Compressor Type Hermetic scroll type or piston
Power KW 0.75 1.50 2.25 3.00 3.75 4.50 6.00 7.50
Circulating pump Power KW 0.375 0.375 0.375 0.375 0.75 0.75 0.75 1.5
Head m 22 22 22 22 23 23 23 21.5
Refrigerant Type R22/R407c/R134a/R410a
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 0.50 1.00 1.50 2.00 2.50 3.00 4.00 5.00
Evaporator Flow m³/h 0.82 0.98 1.45 1.88 2.42 2.92 3.75 4.85
water capacity 0.028 0.04 0.05 0.05 0.065 0.065 0.13 0.18
Diameter inch 1/2" 3/4" 1" 1-1/2" 1-1/2"
Condensator Type Efficient brass sets corrugated aluminum fin
Fan Type Axial flow
air volume m³/h 1000 2000 3000 4000 5000 6000 8000 10000
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 680 800 1040 1140 1140 1200 1400 1400
W mm 420 480 555 620 620 650 725 725
H mm 720 850 1060 1200 1200 1160 1450 1450
Unit weight Kg 60 90 130 140 170 210 270 350

Model JLSF-12HP JLSF-15HP JLSF-20HP JLSF-25HP JLSF-30HP JLSF-40HP JLSF-50HP JLSF-60HP
Cooling capacity KW/h 37.2 46.5 65 77.5 93 124 155 186
Kcal/h 29,059 37,965 50,805 61,683 74,992 97,675 116,521 156,249
Temperature range 5℃-35℃(Below 0℃ can be customized)
Power supply 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ
Total power KW 11.4 13.62 19.8 22.75 28.3 39.2 46.75 56.1
Compressor Type Hermetic scroll type or piston
Power KW 9 11.25 15 18.75 22.5 30 37.5 45
Circulating pump Power KW 1.5 1.5 2.2 2.2 4 4 4 5.5
Head m 21.5 21.5 22 22 25 25 25 26
Refrigerant Type R22/R407c/R134a/R410a
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volume Kg 7.2 9.1 12.2 15.3 18.6 24.5 30.6 36.8
Evaporator Flow m³/h 5.81 7.6 10.16 12.34 15.2 19.53 23.3 30.52
water capacity m³/h 0.18 0.21 0.28 0.32 0.32 0.61 0.66 0.72
Diameter inch 1.5" 2" 2.5" 3"
Condensator Type Efficient brass sets corrugated aluminum fin
Fan Type Axial flow
air volume m³/h 12000 15000 20000 25000 30000 40000 50000 60000
Protective device High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine size L mm 1400 1750 2000 2000 2200 2000 2000 2400
W mm 725 750 900 900 900 1800 1800 1800
H mm 1450 1500 1770 1770 1770 2200 2300 2300
Unit weight Kg 370 480 590 590 880 1000 1280 1420


Application Industry:


The two-system integrated chiller is suitable for occasions that need to provide cooling water for two different cooling systems, such as the following industries and occasions:

1.Central air-conditioning system: Two-system integrated chillers can provide cooling services for large commercial buildings, factories and public places, such as shopping centers, supermarkets, hotels, hospitals, office buildings, etc.

2.Industrial manufacturing industry: In the industrial manufacturing process, many equipment need to be cooled, such as plastic processing equipment, metal processing equipment, chemical equipment, etc. At this time, it is necessary to use two-system integrated chiller to provide cooling water for these equipment.

3.Pharmaceutical industry: In the pharmaceutical industry, many production processes need to control temperature and humidity to ensure product quality and safety, so chillers are needed for cooling and humidity control.

4.Cooling tower system: In the cooling tower system, cooling water needs to be used for cooling. At this time, it is necessary to use two-system integrated chillers to provide cooling water for the cooling tower.

In short, the two-system integrated chiller is suitable for various industries and occasions that need to provide cooling water for two different cooling systems, such as central air conditioning systems, industrial manufacturing industries, pharmaceutical industries, cooling tower systems, etc.

JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature JLSF-62HP Industrial Air Cooled Water Chillers Low Temperature Constant Temperature

Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

Product Maintenance:


Air-cooled chillers are widely used in the food industry. In order to ensure their normal operation and prolong their service life, regular maintenance and maintenance are required. The following are the maintenance and maintenance points of air-cooled chillers:

1.Clean the filter screen: The filter screen of the air-cooled chiller will accumulate dust and dirt, which will affect the cooling effect, so the filter screen needs to be cleaned every month.

2.Check the radiator: The radiator of the air-cooled chiller needs to be checked regularly to ensure that there is no dust or debris on the surface to maintain a good heat dissipation effect.

3.Check the electrical connection: The electrical connection of the air-cooled chiller needs to be checked regularly to ensure that the wires are not aged or damaged to avoid electrical failures.

4.Check the water level and refrigerant: The water level and refrigerant of the air-cooled chiller need to be checked regularly to ensure that it is within the appropriate range to ensure the cooling effect and stable operation.

5.Regular maintenance: Air-cooled chillers need regular maintenance, including replacing refrigerants, cleaning radiators, checking and replacing motor bearings, etc., to ensure their normal operation and prolong their service life.

In general, the maintenance and maintenance of air-cooled chillers in the food industry is very important, which can avoid failure and damage, and ensure the cooling effect and food safety. It is recommended to formulate a regular maintenance plan according to the usage conditions, and operate in strict accordance with the operating instructions. In case of malfunctions or problems, it is recommended to contact professional maintenance personnel in time to deal with them.